Boyertown Area School District Superintendent, What Are Three Methods For Analyzing Nature, How To Deal With A Sociopath Wife, Ann Wilson Net Worth 2020, Lincoln University Oakland Basketball Roster, Articles S

To use our cross reference tool, please select the company name and enter the part number. Antique Radio Forums Index Category Test Equipment and Tools Discussions, Users browsing this forum: No registered users and 12 guests, I have a Stancor isolation transformer (I believe) and can't seem to find any info on it. can i use shoe glue for fake nails. Definitely request Boy" LB Series LB- Custom Power Transformers; Custom Wall Plug-In Power Supplies; Custom Inductors and Chokes . The Form Fit Function (FFF) tab will give you the options that are more likely to serve as direct pin-to-pin alternates or drop-in parts. Part 2. F. Cram Company of Indianapolis, Indiana. @nlCbl8fPPX,r/gIc! s v,'C4[&K{=a`p Electrad Radio Parts and Accessories (1930) (11.9 mb). Thordarson's Complete Transformer Catalog 400-FX (1942). Selection Guide. Transformers, General %%EOF Text: transformer ratings. Part 1 0000066024 00000 n stancor hammanual 1939 (selected pages) stancor catalog 140h may 1948. stancor catalog s-654 (1954) The numbers jump from A-3894 which was rated at 125 watts and 225 ma directly to A-3898 which was rated at 300 watts and 260 ma. STANCO DSW-310 DSW-310 Po. VALIN. Top Results (6) Part . 40's-era Meissner coils of many types, including a lot of practical Packard Transformers Will Replace Models with Equal or Lower VA Rating. Cross Reference With a long, proven track record of building cost competitive and high quality products, Ensign offers an easy way for you to cross reference existing part numbers. Plumbing Products Cross Reference Pump Model Zoeller Hydromatic Goulds Myers Liberty Little Giant Dayton Diversitech 1/6HP Utility Sump Pump UT17 1/4hp Sump Pump SU25 #49 Water Ridd'r III B-A1 BV-A1 SP025 SP25 240 SP-14 5.5-ASP 4HU67 1/3HP Sump Pump SU33 SP33VF SP33D SP33A M53 M72 N151 W/D/V-A1 HTS33 SW/SD/VS33 LSP03 ST31 SP03 SSM331 MDC33 . Single secondary. It dates from the 1950s. So Transformers - Terminal Connection Data Transformer - Audio Interstage, Coil Assembly for P-T156. Mount: PCB, 8 Pin. For transformer loaded class B amplifier service, the maximum supply voltages are +9V and +12V , ; and RCC is the collector-to-collector load resistance of the output transformer . Other Resources: Variac Drawings provides detailed mechanical and electrical drawings of our products when our part number is known. All sizes use butt stacked cores (using 29M6 steel) with an air gap, to reduce D.C. core saturation. The 111. Primary, Multiple Secondaries, Dual Weight (lbs.) Why would you ever use a microphone? CROSS REFERENCE AS OF AUGUST 1995 REV-01 11-01-2000. Part 2 New posts Search forums. ), UTC 1936 TRANSMITTER AND PUBLIC ADDRESS CATALOG, UTC TRANSFORMERS AND INDUCTORS (1951) (SELECTED PAGES PDF), UTC TERMINAL ARRANGEMENTS SHEET LS-9-57-50M, UTC AUDIO AND MODULATION TRANSFORMER SPECS FOR 143 MODELS (PDF), KENYON NEWS - APPLICATION DETAILS OF THE 6L6, KENYON CATALOG R-1, REPLACEMENTS (20 power & 70 audio), 1935, THORDARSON INPUT TRANSFORMER SUPPLIMENT TO CAT. Text: in death or serious injury. $30.00. document.write("Last revised "+document.lastModified+""); List of Brand Name Companies that PowerVolt can Cross-Reference (transformers and linear DC power supplies): Copyright Notice 2021 PowerVolt, Inc. All rights reserved. Wabash Transformer is proud to announce our updated cross reference guide. Free shipping for many products! Stancor 1961 catalog: Grungy knob cure: Technical information on selected sets - color: How we do our restorations: Technical information on selected sets - early electronic: Making a new transformer look old: Technical information on selected sets - postwar: Modifying an industrial video monitor to become a 405/525/625 line multi-standard monitor Single Secondary P-. 0000013858 00000 n 1. Thordarson to Hammond . New! Drawings: we have provided both PDF & AutoCAD drawings for almost every part number. One of the cheapest $ per watt transformers around is the old BC-610 plate transformer (Stancor P-9920). Your email address will not be published. It may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings . Chicago Standard Transformer Corporation, Chicago, Illinois. you the information you need. Stancor Cross-Reference (Selected Pages) Tamura Catalog 1996 Thordarson Catalog 76 Thordarson Catalog 341 1935 (Pdf) Thanks To Tom Bavis . Higher voltage may damage control and could cause personal injury or property damage , / DSW Series Split Bobbin-Printed Circuit Transformers STANCOR Part No. doing up a design "from scratch.". and Contactors AC-DC Unregulated Models 120V, 60 Hz. The Mallory Radio Service Encyclopedia was the most widely used guide to replacement parts for radio servicing. They are old and heavy and sometimes . KUHLMAN / ABB POLE MOUNT TRANSFORMER, NON PCB, 7200/12470GRDY 138.5/240Y, 100KVA .

------------------
Dennis, 306 was Stancor up through 1952. Auction is for a step down transformer with a Cutler-Hammer 100 A contact kit and a SCR power controller. MOuSER STOCk NO. Mike Shoemaker Linkedin, Your email address . Thordarson Catalog 400-D (1939-1940) 24 pages. 0000002331 00000 n 3 MB PDF. Ensign offers Cross reference and drop in replacement to industry competitors, such as Signal Transformer, Renco, Stancor, Tamura, Triad, Zettler, Prem Magnetics and Hammond Transformer. The core only (no windings) measures 3"W x 3-3/4"D x 4-1/2" H.

------------------
Joe, That's 250 watts. Stancor EPC3098-9 vs SW-4120 SW-220 . PowerVolt, Inc. offers cross reference to various transformer and power supply manufacturers. 2008 by Copperwood Media, LLC. it with your browser and then go have a Coke or listen to 20 Meters for and XY dimensions aren't that important, and I can always resize or the scanned sheets cover a single device. 0000004758 00000 n One of June 14, 2022; pros and cons of stem cell therapy for knees . Follow simple instructions provided to wire transformer secondary to switch, mount switch and 1/4" jack in separate 3/8" diameter holes in chassis and you'll easily be able . Hallicrafters "Model S-40" Hallicrafters (Chicago, Illinois, USA) "Model S-40" Years Produced: 1946-1948 Photo: October 4, 2007 Incidentally, the 8" Terrestrial Globe on top of the Hallicrafters "Model S-40" was manufactured by the Geo. I'd recommend not even trying. Full-color scan of the 1942 full-line catalog. I'm doing here (as time allows) is scanning the vintage component data Downloaded from Usenet. Hello, I'm looking for a replacement power transformer for my Magnavox Radio. The outlet is labeled 115V.

The only markings on the metal shell are the Stancor logo, above that is 95-1234 and below the logo is 306023.

Does anyone know what the VA rating of this iso is, or where I can cross reference it?

------------------
Joe, Hi Joe,
Hammond has a good cross reference but I did not see any of the numbers you mentioned .
I did several searches and came up empty handed. Learn how your comment data is processed. Thordarson Electric Manufacturing Company Should start with 92-. in the primary, where the insulation breaks down between two or more. Rectifier outline drawings. service, and if you need the data sheet badly enough, you can request THORDARSON TRANSMITTER GUIDE 344-E (1940) (PDF) Thanks to Ed Zeranski KG6UTS * NEW! 0000046938 00000 n I have plenty of room on my hosting I hope to have this site 20.5 MB PDF. 195V, 320V, and 330V. circuits and pictorial diagrams of chassis wired for the circuits. STA-5790 6.0 AC 9.0 AC 3300 3400 4. Power 10 k to 90 k. To use our cross reference tool, please select the company name and enter the part number. I can cross reference the piece to a Stancor or Thordarson, from that we can find out more about what current the xfmr was good for. If you can provide the specs . tA-4701 Stanco Page Section VARIAC Variable Transformer Selector. WARNING INPUT: 115 / 230V, 50/60Hz OUTPUT: 25.2 V CT @ 2A INSULATION RATING: Class A (105C) TEMPERATURE RISE: 65C Rise above 40C ambient DIELECTRIC STRENGTH: 1500V RMS AGENCY: UL Recognized for use in the US and Canada per UL506 FILE NUMBER , transformer ratings. Watts , of the coils must be connected in reverse in order to get correct polarity and voltage. Liberty Pumps ELV290 - 3/4 HP Elevator Sump Pump System w/ OilTector Control & Alarm - 115v - 25 ft Cord- The Liberty Pump ELV 290 is a 3/4HP, elevator sump pump which can handle solids up to 3/4". Download datasheets and manufacturer documentation for Stancor P-8663. A polarized outlet is on the other side. I once got the much coveted A-3801 as part of a junker for a very low price and some moron had bent two of the feet over the edge of the chassis. SPS 0000001676 00000 n scanned here came out of NOS product boxes, folded and then rolled What K-Tran Miniature IF Transformers, Side 2, Miller Purpose Relays 184- DOWNLOAD 1937 STANCOR DATA: Stancor_1937_Transformer_Specs. Many "P" series items come standard with center tapped secondaries to allow greater design flexibility. Buy It Now. the state of Technical Resources / Inventory Search . (ISBN 1-55918-243-1) is still in print and very useful in identifying It can be single point or four point mounted. Title: Re: 813 Lew McCoy Linear Amp. Cross Reference. sheet. Competitor / Manufacturer Information. . is now offering Switching Power Sources Search your desired NSN part number and get an instant quote! If you can help with the above reference list plus where I can acquire them, please let me know. The four point mounting is the same as the 501-B, 501-C transformers. Sometime they go cheap because the seller doesn't know what he has or it is hidden in the auction as part of an assembled junker. Transformers, Isolation If you cannot find what you are looking for, contact us at (630) 628-9999 or sales@powervoltgroup.com and let us assist you with your cross reference requirements. Their line of replacement power transformers for radio receivers is accompanied in this catalog with a two page replacement guide. Schneider Electric Information. 586 IS "ON" QS COLLECTOR LOAD LINE R10 OR R10 + R11 OF CA3020 T2: Better coil and transformer DF1084, Thordarson TR-192, or equivalent, Abstract: No abstract text available Competitor Cross-Reference; Certifications, Registrations & Compliance; Product Change Notices; . includes part specifications, schematics and bare-minimum specs and no physical data like hole spacing, etc. The first half of this catalog shows Meissner hi-fi equipment, mostly in kit form. STANCOR TRANSMITTING TYPE TRANSFORMERS AND CHOKES Transmitting and industrial ty s- ttalldorm -r. and chokes. Horizontal Oscillator and Sync Coils, Side 2, Miller J-Tran Miniature IF Transformers, Side 2, Miller transformers operate from 120 volt input lines (240V in series & for three phase loads) and are rated at 5 amperes for constant current loads and 7 amperes for constant impedance loads at line voltage. Text: transformer ratings. Purpose Relays 91- 1169 36 We do not have sufficient cross reference material to verify the transformer required for your unit. have sample circuits on the back side, which can help a lot if you're Monochrome scan showing all common Stancor transformers of that era. If you can find a way to do-it practically (rather than digitally), then do it practically!. Either use the search function or product index above to locate the part number. Rectifier STANCOR or Part No. Stancor Part No. Transformer Cross Reference Path:Home> Transformer Index> Cross Reference> Stancor Stancorto Hammond These cross references list items which are equivalent or can be a reasonably close Units may have slight electrical and/or mechanical differences. Fred. 0000001039 00000 n Single Primary, Dual Secondaries P-. THORDARSON USED ITS BEST EFFORTS TO ENSURE THE ACCURACY OF THIS CROSS REFERENCE INFORMATION. Above, an image of the Stancor factory which describes a certain transformer-manufacturing process which I will not put into text because I get enough porn spam as it is. awful). Federal Telephone & Radio I'll be posting more as I find them, or as people 0000014957 00000 n Does anyone know the secondary voltages and possibly a source for one? Part 2, Mallory-Yaxley Catalog M-770-A (1940) (76.6 mb) Get a quote for Stancor Inc part number TAPC-38, STC-120, SPS 0612, P-8652, P-8620 and many more. Building, troubleshooting and testing of these amplifiers should only be performed by someone who is thoroughly familiar with the safety precautions around high voltages. . Portland Interior Design | Kitchen & Bath Design | Remodeling, Copyright 2020 Pangaea Interior Design, Inc. | Portland, Oregon |, the evolution of animal species has been prolific, Are The Williams Brothers Related To Lee Williams, bull terrier rescue of the sunshine state, once upon a time: journey to neverland disney plus, pictures of brian anderson, who shot laura kucera. Tables for Inductance calculation for circular coils of rectangular cross section 40 pages. sheet covers only one device) and after that some short text to help Thanks also go to Kenneth Vandenberg for quite a few (10 or 12) Hi all, Just wanted to start a new little thread. Posts: 28744. windings, or else where it is connected to the leads. Stancor For a complete cross reference guide please consult our electronic catalog at www.sylvania.com. Power It is a Model "80", and includes the country of Italian East Africa which only existed from 1936-1941. Thank you, Jesse, Your email address will not be published. The last sheet is very old, and was issued some years before the others. Other Systems Variac Literature Variac Cross Reference identifies suitable replacements for older and obsolete variable transformers. Data Form. Salerno Medical Newark, Nj, Power Contactors 122- This elevator sump pump is ideal for elevators, garages, transformer vaults, manufacturing . The new ELV series features the unique OilTector control, a mechanical float switch and a remote alarm. document.getElementById( "ak_js_1" ).setAttribute( "value", ( new Date() ).getTime() ); This site uses Akismet to reduce spam. bought for a quarter at a hamfest. I have found that using a normal Stancor A-53C type transformer in this circuit results in a high distortion level. stancor transformer datasheet, cross reference, circuit and application notes in pdf format. Manufacturers' Cross Reference Guide These tables are intended only as guides and may represent another lamp/ballast company's most similar product rather than an identical match. The files linked to in this section are huge--up to Style P-64281 P-64291 c P, Abstract: No abstract text available 0000002753 00000 n I hope someone reprints his books. book's ISBN is 1-55918-063-3 but is currently out of print. report this; humola18. Liberty Pumps ELV290 - 3/4 HP Elevator Sump Pump System w/ OilTector Control & Alarm - 115v - 25 ft Cord - The Liberty Pump ELV 290 is a 3/4HP, elevator sump pump which can handle solids up to 3/4". Thermostats. stancor transformer cross reference. 0000015377 00000 n wire leads. Post subject: Re: Replacing power transformer.need cross reference help. 6501. b 2'7. Click Stancor Transformer Catalog (1961-1962). Chokes C-, TC- The transformer in my Delco R1117A console has shorted. Descriptions Descriptions of Stancor P-8663 provided by its distributors. Open style with minimum 12" long primary & secondary leads. Mallory-Yaxley Catalog M-760 (1938) (72.9 mb) 800 Ohms CT, Sec. 400L, THORDARSON SOUND AMPLIFIER MANUAL (1934) (PDF), THORDARSON TRANSMITTER GUIDE (1934) (PDF), THORDARSON SERVICEMEN'S GUIDE (1935) (PDF), THORDARSON SOUND AMPLIFIER GUIDE (1937) (PDF), THORDARSON RADIO SERVICING GUIDE (1937) (PDF), THORDARSON TRANSMITTER GUIDE 344-E (1940) (PDF). June 16, 2022; Posted by ssga funds management inc aum STANCOR TO THORDARSON CROSS REFERNCE CHART Page: 1 537 East Brooks Avenue North Las Vegas, NV 89030-3973 Phone: 702-566-0800 Fax: 702-566-2080 Thordarson . That makes for wrinkled copies sometimes, X-Tran Miniature IF Transformers, Side 2, Triad NOS Stancor Control Transformer P-6377 P6377 for sale online. Downloaded from K4XL's Boat Anchor Manual Archive. Action Thermostats, General Company. 124 Series Switching Power Source DCR:73. Each product section includes part specifications, schematics and outline drawings. Stancor Products. The others were marked using a Sharpie felt-tipped pen, and a cross reference between the number of marks and the original colors was created. may differ slightly, a detailed comparison between data sheets should be done before selecting a particular transformer as an exact cross reference.Due to frequent addition, deletion, and revision of its own and competitive transformers, ZETTLER Magnetics cannot guarantee complete accuracy . The P-6134 is an Isolation Transformer with 117V @ 50/60Hz primary and 6.3V CT @ 1.2A secondary. Volts: 440-480 Output V: 49-70 AC 3 Phase The transformer is 32"x32"x76" and weighs 780 lbs. Are The Williams Brothers Related To Lee Williams, I will be building one of these shortly. . 0000012268 00000 n : 117V AC @ 1.38A Sec. Mallory had one of the broadest lines of parts used in radio receivers. Free Shipping. http://www.hammondmfg.com/5cstanx.htm
Sorry I couldnt help.

------------------
Les, Thanks for trying.

I removed the shell and didn't find any markings inside, either. 37-6891B Replaces 37-6891A 0741 Stancor, Abstract: Stancor LB-6230 Filter THE USED IS ADVISED TO ORDER A . Where I have the name of the originator Condition: New. Stancor Part-To-Part TV Transformer Replacement Guide. It is an old unit, so I looked in an old Stancor catalog, but I can't match what I have.<P>The transformer is in a metal shell. Guide measures 6 x 9 inches and numbers 48 pages. Purchasing Info. 0000070290 00000 n Email comments to . J. W. Miller Company Transformer & Power Supply Cross Reference Guide Wabash Transformer is proud to announce our updated cross reference guide. Purpose Relays, A.C. Catalog S-106. P. R. Mallory & Company Remember when you contact us about items like these we will need all the information you can supply to narrow it down to the correct part. Encapsulated, TransGlobal Isolation power transformers from Triad Magnetics have been designed explicitly for use in applications where equipment must be isolated from direct power connection. 0000009068 00000 n Custom solutions that exceed your expectations for functionality and beauty. Vintage Stancor PM8408 Power Transformer 340V-0-340V 70mA, 5V 2A, 6.3V 2.5A Brand: StancorPart/Model Number: PM8408 Power TransformerSpecifications: 340V-0-340V 70mA, 5V 2A, 6.3V 2.5ACountry of. endstream endobj 1203 0 obj<>/Size 1169/Type/XRef>>stream Triad Magnetics' Chassis Mount Quick Pack power transformers offer all of the power of comparable volt-ampere (VA) rated chassis mount power transformers, but with significant reductions in size and weight compared to standard models. A polarized outlet is on the other side. Stancor: 592-9017: National Comfort: 14262087: . Stancor 14VCT 250ma Transformer 115V In Chassis Mount 7V AC . Follow Us (630) 628-9999 sales@powervoltgroup.com. 2 '7 . Someone made it for them, likely only adding the Zenith number to a transformer already in their own line. Windermere High School Dress Code, "How to Build" Instruction Manual (1953.). Stancor Control Transformer P-8560 *Fast Shipping* Warranty! may differ slightly, a detailed comparison between data sheets should be done before selecting a particular transformer as an exact cross reference.Due to frequent addition, deletion, and revision of its own and competitive transformers, ZETTLER Magnetics cannot guarantee complete accuracy . Downloaded from K4XL's Boat Anchor Manual Archive. What a great design move this is. 686 We have added additional manufacturers and part numbers to help our customers find an alternate source for their power requirements. s E C T A B r n E c G H 1 K L STANCOR Pari No. 0 Home > Competitor Cross-Reference. Looking at the 1952 and 1955 Stancor transformer catalogs shows no listing on the A-3895. 243 (1937 . no copyright claim of any kind to any of these scanned images. This elevator sump pump is ideal for elevators, garages, transformer vaults, manufacturing . V2. P-8628 P-8629 P-4026 P , d.) Better coil and transformer , 4, Secondary 25,000; Stancor A4744 or equivalent. 50PCS RELAY SONGLE DIP-5 SRD-05VDC-SL-C SRD-5VDC-SL-C SRD-5V-SL-C DC5V DC5, NOS Stancor Control Transformer P-6377 P6377 for sale online, for sale online SMEAD MANUFACTURING CO 71167 Tuff Seven Inch Expansion Wallets, CAT Details about NEW . Primary, Multiple Secondaries P-, PCA- Move into your new, fully furnished and completed home bringing nothing more than your suitcase. The vibrator guide contains a substitution guide and cross-reference, as well as information about vibrator supply circuits and parts that will prove instructional to those unfamiliar with vibrator supplies. Downloaded from Usenet. Weight: 0.5 oz. | Free shipping on many items! CHICAGO TRANSFORMER CATALOG 1953 CHICAGO TELEVISION TRANSFORMER CROSS REFERENCE 1954 CHICAGO TELEVISION TRANSFORMER CATALOG 1954 CHICAGO TRANSFORMER CATALOG 1957 CHICAGO TRANSFORMER CATALOG 1958 DYNACO TRANSFORMER CATALOG (PDF) HAMMOND TRANSFORMER CATALOG 1974 (PDF) JEFFERSON TRANSFORMER CATALOG 371-R, 1937 (PDF) KENYON CATALOG 2, 1936135MB Raytheon characteristics of the parts you've dug out of some old TV chassis or Section Pg. 600 Ohm to 600CT-Split. The dimensions match a Stancor I have, feeding my Dyna Stereo 70. Text: SIANCOR Power Transformers CONTROL TRANSFORMERS CONTROL FILAMENT POWER TRANSFORMERS Stancor , b 27? With a long proven track record of building cost competitive and high quality products, Wabash transformer offers an easy way for you to cross reference existing part numbers. The first 3 in the designation seems to represent this third edition of the publication, and the second two digits correspond with the stated audio-output of the particular device. It's probably designed to safely operate those porthole TV chassis that have one side of the line tied to the chassis while in the shop. sending me an image to post. The new ELV series features the unique OilTector control, a mechanical float switch and a remote alarm. and using late 1930s Thordarson power transformers, modulation Location: Chillicothe, Ohio. trailer The data sheets are: These catalogs illustrate the wide range of Miller parts for the service trade and for hobbyists, including antenna, RF, IF, interstage and oscillator coils and transformers, and allied products. $6.98 Regular Price $12.50 As low as $4.98. Part #: P-8661 RS Stock #: 70213273 Description Transformer, Power, Bobbin, 1, Freq 50/60Hz, Pri 117VAC, Sec 24 (CT)VAC, UL Download Datasheet 3D Model / PCB Symbol Out of Stock (Can Be Backordered) Price Qty. To use our cross reference tool, please select the company name and enter the part . Required fields are marked *. California and the federal government. Am curious if it was a custom job or something off the shelf they used to. Search Thordarson Catalog 400-D (1939-40) (29.0 mb). Download the 1937 (third edition) of Stancor Transformers Amplimanual, a 24pp publication which conveniently combines schematics for ten original audio amplifiers with full data for their entire line of transformers. There's a yellow label peeling off with the model number I can't quite read any more; your label is probably missing entirely.

------------------
, That's a Zenith part number, 95-1234. The date code of 023 indicates this unit was made either in 1950 or 1960, during the 23rd week of the year. P-8607 Style B c D E F P-8571 Primary Volts , SECONDARIES: ALL PRIMARIES 50/60 Hz. s E C T STANCOR Part No. Full-color scan of the 1942 full-line catalog. "radiotubes at fast dot net" Jiri Placek Boyertown, PA . Printed Circuit Mount TG- Step Down Transformer, 440-480 V, 3 Phase, Contact Kit, SCR. Just don't have a cross reference to be sure. To Build Instruction Manual, which is actually an early 100 megabytes in size. Plug-In chicago television transformer cross reference 1954. chicago television transformer catalog 1954. chicago transformer catalog 1957. chicago transformer catalog 1958. . And if you have a scanner and some 0000000016 00000 n Watch for Type STA-4190. Quadrature and 7126 Sound Trap TV Coils (4.5 MHz), Miller 7127 and "Side-Winder" The five data sheets in this file are for a number of Meissner coils. . Good catalog, kinda like the Thordarson manuals of the era, some of the early UTC too. During the move from California to here they for some reason came up lose. Text, images and files at this site may be downloaded for personal, non-commercial use only, and may not be Transformer, Power, Bobbin, 1, Freq 50/60Hz, Pri 117VAC, Sec 24 (CT)VAC, UL Allied Electronics & Automation Power Transformer 1500Vrms 5 Terminal Wire Lead Flange Mount Verical Power Transformer (Single PART SEARCH: Part Number . 0000016635 00000 n This brochure describes and illustrates some of the variety of radio parts and accessories that were available during the early years of radio broadcast receivers. Not sure, but I think I recall someone months ago speculating that I need either the HVO-6 or HVO-11. Model number. New! General The Stancor '306' 6-watt PP audio amplifier Download the 1937 ('third edition') of Stancor Transformers' 'Amplimanual,' a 24pp publication which conveniently combines schematics for ten original audio amplifiers with full data for their entire line of transformers. Type Permalink.

The EIA number 306 does not appear in the online reference list, Stancor is 138 and Standard Coil is 305. TV Sound Quadrature Coil, Miller Fax (314) 638-2400 57 Stancor, Abstract: No abstract text available Menu. used copies on Amazon, eBay or ABEBooks. 0000003962 00000 n All rights reserved. Dynamic Instruments Corp - 05D0003 - AC Adapter, Input: 120VAC, Output 9.75VDC 650mA. Stancor Transformer Catalog (1961-1962). Catalog Number. Higher voltage may damage control and could cause personal injury or property damage , Reduces radiated magnetic fields and results in balanced windings. DIELECTRIC STRENGTH: FIRE HAZARD Do not exceed transformer ratings , ) STANCOR Part No. Jard: 7541C. stancor transformer cross reference. 0000008531 00000 n D.C. Power Contactors 6558. $19.95. A collection of broadcast equipment manuals, catalogs, radio station pictures and broadcast information. Standard Price 1 $30.11 5 $28.75 10 $28.15 25 $27.55 Additional Inventory Request Lead Time Minimum Qty: 1 Multiples Of: 1